Go to the documentation of this file.
14 #ifndef TOBII_RESEARCH_CALIBRATION_H_
15 #define TOBII_RESEARCH_CALIBRATION_H_
Definition: tobii_research_calibration.h:121
TobiiResearchCalibrationStatus status
Definition: tobii_research_calibration.h:162
@ TOBII_RESEARCH_CALIBRATION_EYE_VALIDITY_VALID_AND_USED
Definition: tobii_research_calibration.h:82
TobiiResearchCalibrationEyeData right_eye
Definition: tobii_research_calibration.h:115
Definition: tobii_research.h:379
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_hmd_based_calibration_leave_calibration_mode(TobiiResearchEyeTracker *eyetracker)
Leaves the hmd based calibration mode.
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_screen_based_monocular_calibration_discard_data(TobiiResearchEyeTracker *eyetracker, float x, float y, TobiiResearchSelectedEye eye_to_calibrate)
Removes the collected data associated with a specific calibration point.
@ TOBII_RESEARCH_CALIBRATION_EYE_VALIDITY_UNKNOWN
Definition: tobii_research_calibration.h:87
TobiiResearchCalibrationStatus
Definition: tobii_research_calibration.h:26
Definition: tobii_research_calibration.h:158
Definition: tobii_research_calibration.h:93
TobiiResearchNormalizedPoint2D position_on_display_area
Definition: tobii_research_calibration.h:97
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_screen_based_calibration_compute_and_apply(TobiiResearchEyeTracker *eyetracker, TobiiResearchCalibrationResult **result)
Uses the collected data and tries to compute calibration parameters.
#define TOBII_RESEARCH_CALL
Definition: tobii_research.h:38
TobiiResearchNormalizedPoint2D position_on_display_area
Definition: tobii_research_calibration.h:125
@ TOBII_RESEARCH_SELECTED_EYE_BOTH
Definition: tobii_research_calibration.h:62
TobiiResearchCalibrationSample * calibration_samples
Definition: tobii_research_calibration.h:129
TobiiResearchCalibrationEyeValidity
Definition: tobii_research_calibration.h:68
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_hmd_based_calibration_collect_data(TobiiResearchEyeTracker *eyetracker, float x, float y, float z)
Starts collecting data for a calibration point.
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_hmd_based_calibration_enter_calibration_mode(TobiiResearchEyeTracker *eyetracker)
Enters the hmd based calibration mode and the eye tracker is made ready for collecting data and calcu...
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_screen_based_monocular_calibration_compute_and_apply(TobiiResearchEyeTracker *eyetracker, TobiiResearchCalibrationResult **result)
Uses the collected data and tries to compute calibration parameters.
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_screen_based_calibration_collect_data(TobiiResearchEyeTracker *eyetracker, float x, float y)
Starts collecting data for a calibration point.
@ TOBII_RESEARCH_CALIBRATION_SUCCESS
Definition: tobii_research_calibration.h:34
TobiiResearchCalibrationPoint * calibration_points
Definition: tobii_research_calibration.h:143
struct TobiiResearchEyeTracker TobiiResearchEyeTracker
Definition: tobii_research.h:310
@ TOBII_RESEARCH_SELECTED_EYE_RIGHT
Definition: tobii_research_calibration.h:57
Definition: tobii_research_calibration.h:139
TobiiResearchCalibrationStatus status
Definition: tobii_research_calibration.h:151
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_screen_based_calibration_enter_calibration_mode(TobiiResearchEyeTracker *eyetracker)
Enters the screen based calibration mode and the eye tracker is made ready for collecting data and ca...
@ TOBII_RESEARCH_CALIBRATION_EYE_VALIDITY_INVALID_AND_NOT_USED
Definition: tobii_research_calibration.h:72
@ TOBII_RESEARCH_CALIBRATION_FAILURE
Definition: tobii_research_calibration.h:30
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_screen_based_calibration_leave_calibration_mode(TobiiResearchEyeTracker *eyetracker)
Leaves the screen based calibration mode.
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_screen_based_calibration_discard_data(TobiiResearchEyeTracker *eyetracker, float x, float y)
Removes the collected data associated with a specific calibration point.
TOBII_RESEARCH_API void TOBII_RESEARCH_CALL tobii_research_free_screen_based_calibration_result(TobiiResearchCalibrationResult *result)
Free memory allocation for the calibration result received via tobii_research_screen_based_calibratio...
size_t calibration_point_count
Definition: tobii_research_calibration.h:147
Definition: tobii_research_calibration.h:107
TobiiResearchSelectedEye
Definition: tobii_research_calibration.h:48
@ TOBII_RESEARCH_CALIBRATION_SUCCESS_LEFT_EYE
Definition: tobii_research_calibration.h:38
size_t calibration_sample_count
Definition: tobii_research_calibration.h:133
TobiiResearchCalibrationEyeData left_eye
Definition: tobii_research_calibration.h:111
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_hmd_based_calibration_compute_and_apply(TobiiResearchEyeTracker *eyetracker, TobiiResearchHMDCalibrationResult *result)
Uses the collected data and tries to compute calibration parameters.
@ TOBII_RESEARCH_CALIBRATION_EYE_VALIDITY_VALID_BUT_NOT_USED
Definition: tobii_research_calibration.h:77
#define TOBII_RESEARCH_API
Definition: tobii_research.h:37
@ TOBII_RESEARCH_SELECTED_EYE_LEFT
Definition: tobii_research_calibration.h:52
TobiiResearchCalibrationEyeValidity validity
Definition: tobii_research_calibration.h:101
TOBII_RESEARCH_API TobiiResearchStatus TOBII_RESEARCH_CALL tobii_research_screen_based_monocular_calibration_collect_data(TobiiResearchEyeTracker *eyetracker, float x, float y, TobiiResearchSelectedEye eye_to_calibrate, TobiiResearchSelectedEye *collected_eyes)
Starts collecting data for a calibration point.
TobiiResearchStatus
Definition: tobii_research.h:45
@ TOBII_RESEARCH_CALIBRATION_SUCCESS_RIGHT_EYE
Definition: tobii_research_calibration.h:42